Mold rack quotation based on mold weight, number of levels and pull-out drawer type
A mold rack (die storage rack, roll-out mold rack) is a specialised rack for plastic injection, aluminium die-casting and metal stamping plants, where each mold weighs from a few hundred kilograms to several tonnes and is the most valuable asset in the factory. Roller drawers that pull out 100% let the crane lift the mold straight from above – much safer and faster than ordinary racks. The price depends on mold size and weight, number of levels, pull-out or fixed levels, steel section, coating and accessories such as electric hoists and oil trays.
An 11-step procedure from anchoring frames, fitting rails and 100% pull-out drawers to locks and test run; a 33-item QC acceptance checklist you can print in the plant.
Quick summary
Long Quyen mold racks carry 500–3,000 kg per level, frame height 1,500–3,000 mm, level depth 600–1,500 mm, bay width 1,000–2,000 mm, typically 2–4 levels, with H/I steel sections and box sections 3.0–6.0 mm thick and oil-resistant epoxy powder coating. Each system is designed for your largest and heaviest mold, so the price changes mainly with mold weight, number of bays and levels, 100% pull-out drawers or fixed levels, and accessories such as electric hoists, oil trays and drawer locks.
When does a plant need a dedicated mold rack?
Plastic injection plants
Small to large injection molds (300 kg – 2 t) need fixed storage without stacking, and the right mold must be found in minutes to reduce machine downtime.
Stamping, die-casting and punching plants
Sheet stamping dies, heavy casting molds and high concentrated loads require thick steel sections, load-rated drawers and base plates anchored to the floor.
Mold, jig and heavy tool stores
Jigs, shafts and heavy machine parts are also stored well on mold racks – pull out the drawer and lift straight up instead of threading slings inside a tight bay.
When should you not compare mold rack prices per unit only?
- When molds vary in weight: the rack must be designed for the heaviest mold in the group, and bays for lighter molds use the same section.
- When the plant has no crane: an electric hoist on top of the rack or a forklift aisle is needed – the solution and cost change significantly.
- When the floor is weak or cracked: a drawer pulled out under heavy load creates a large tipping force, requiring thick base plates and proper anchoring.
- When the aisle in front is narrow: pull-out drawers need an aisle at least about 600 mm wider than the drawer depth; otherwise the layout must change.
What determines the mold rack price
1. Mold weight per level
From 500 to 3,000 kg per level. This is the key factor for the steel section, roller rails and steel drawer.
2. Mold and bay size
Bay width 1,000–2,000 mm, depth 600–1,500 mm; the larger the mold, the heavier the drawer and frame.
3. Number of levels and frame height
Typically 2–4 levels, 1,500–3,000 mm high; must be calculated against the crane hook height at maximum lift.
4. 100% pull-out or fixed levels
Roller drawers with rails, rollers and locks cost more than fixed levels served by forklift, but handling is much safer and faster.
5. Lifting equipment and accessories
Electric hoist on top of the rack, oil tray under each mold, open/closed drawer locks and mold ID labels are optional items.
6. Coating and plant environment
Oil-resistant epoxy, powder coating or hot-dip galvanising depending on oil, humidity or chemicals.
Reference quotation table by mold rack configuration
Each mold rack is designed by Long Quyen for the actual size and weight of your molds, so we quote each configuration rather than publishing a general price. The table below helps you identify the right configuration before sending a request.
| Reference configuration | Typical specifications | Suitable applications | Quotation |
|---|---|---|---|
| Fixed-level mold rack | Steel section frame, molds handled by forklift, 2–4 levels | Medium molds, plants with forklifts, optimised budget | Quoted by configuration – sent within 2 working hours |
| Pull-out mold rack – small/medium molds | 500–1,000 kg/level, roller drawer pulls out 100% | Small and medium injection molds | Quoted by configuration – sent within 2 working hours |
| Pull-out mold rack – heavy molds | 1,000–3,000 kg/level, H/I steel 3.0–6.0 mm thick | Large injection molds, stamping and casting dies | Quoted by configuration – sent within 2 working hours |
| Mold rack with electric hoist | Electric hoist on top, oil trays, drawer locks | Plants without or with limited crane capacity | Quoted by configuration – sent within 2 working hours |
An accurate quotation is based on the size and weight of each mold group, number of molds, lifting equipment and the layout of the mold area. No drawing yet? Use the mold rack design tool to get the number of bays and a preliminary bill of materials.
Why can mold rack prices differ so much for the same number of bays?
Different mold load
A 500 kg mold and a 2.5 t mold require completely different steel sections, rails and drawers.
Different level type
100% pull-out drawers have roller rails and locks; fixed levels are simpler but need a forklift and a wide aisle.
Different lifting equipment
With an existing crane no hoist is needed; otherwise an electric hoist on top of the rack is a separate item.
Different finishing
Oil-resistant epoxy, galvanising, oil trays, mold ID labels and installation in a running plant all change the budget.
What to send for a fast, accurate quotation
- List of mold groups: size (width × depth × height) and weight of the heaviest mold in each group.
- Current number of molds and expected growth.
- Size of the mold area, crane hook height at maximum lift, positions of columns and doors.
- Existing lifting equipment: overhead crane, gantry crane, hand pallet truck, counterbalance forklift.
- Pull-out or fixed levels, oil trays, coating requirements.
- Photos of the plant floor and required installation schedule.
Quick comparison: mold rack vs pallet rack and medium-duty rack
| Criteria | Medium-duty rack | Selective pallet rack | Mold rack |
|---|---|---|---|
| Suitable load | 200–500 kg/level | By pallet | 500–3,000 kg/level, concentrated load |
| Handling | Manual | Forklift | Pull drawer out 100%, lift from above |
| Product protection | Medium | Medium | Molds fixed, not stacked, with oil trays |
| Best for | Components, cartons | Palletised goods | Injection molds, stamping dies, heavy jigs |
Some mold rack projects delivered by Long Quyen
Long Quyen has designed, manufactured and installed mold racks for the DragonJet plant, roll-out racks for steel dies in mechanical workshops, and mold racks for Dong A, HT Vietnam, Omega and many plastic injection and metal stamping plants. See more on mold racks, mold storage rack prices and stamping die racks.
Technical and safety notes for mold racks
When a drawer is pulled out with a heavy mold, the centre of gravity moves outward and creates a large tipping force – so base plates must be thick enough and anchored to the concrete floor with proper expansion anchors. Each drawer needs locks in the closed and fully open positions so it cannot roll when the plant vibrates or the floor slopes; on single-sided racks pull out only one drawer at a time. The aisle in front must be at least about 600 mm wider than the drawer depth for people and lifting equipment. See also OSHA on materials handling and HSE on lifting equipment (LOLER).
Get a mold rack quotation based on mold size and weight
Send your mold list (size, weight), number of molds, lifting equipment and photos of the mold area so Long Quyen engineers can propose the drawer type, number of levels and frame section – quotation within 2 working hours, free on-site survey.
Get a free quote & consultation
Leave your details – a Long Quyen engineer will call you back within 2 working hours.
- Nearly 30 years of manufacturing
- ISO 9001:2015
- 500+ projects
- Free on-site survey
Frequently asked questions
How much weight can a mold rack hold per level?
Long Quyen mold racks are designed for 500–3,000 kg per level depending on steel section, bay width and drawer type. Each system is calculated for your heaviest mold.
Should I choose 100% pull-out drawers or fixed levels?
Pull-out drawers let the crane lift molds straight from above – safer and faster, suitable for plants with a crane or hoist. Fixed levels cost less and suit plants that handle molds by forklift with a wide aisle.
How are molds lifted if the plant has no crane?
An electric hoist can be mounted on top of the rack to lift molds in place, or fixed-level racks can be used with a forklift. Long Quyen advises based on mold weight and layout.
Is a mold rack priced per bay or per tonne of steel?
Long Quyen quotes the complete configuration: number of bays, levels, load per level, drawers, accessories and installation. Steel weight is only part of the cost.
Are oil trays necessary?
Recommended for injection molds and molds with anti-rust oil: a tray under each mold keeps the plant floor clean and safe at little cost compared with the whole system.
What is the warranty on mold racks?
Long Quyen provides a 24–60 month warranty depending on rack type and accessories; the exact period is stated in the contract.
Contact the Long Quyen engineering team
If your plant needs to reorganise its mold area, shorten mold changeovers or improve safety when handling heavy molds, Long Quyen offers a free survey, load calculation and layout before quoting.
- Hotline: 0903422179 (Mr. Dat) – 0903412296 (Mr. Hien) – 0903434374 (Mr. Cam)
- Email: contact@giakelongquyen.com – contact@longquyen.com
- Office: 79 Dao Tan St., Giang Vo Ward, Hanoi, Vietnam
- Factory: 1085 Phuc Dien St., Xuan Phuong Ward, Hanoi, Vietnam (Mon–Sat, 7:30–17:00)
- Warranty 24–60 months depending on rack type and accessories · ISO 9001:2015